Intergas boiler fault codes: full list and what to do
Intergas prints its fault code tables inside its installation manuals rather than on its website, so these codes are hard to look up. Find your range first, then your code, then the safe next step. Smart Plan cover is a capped service plan, not insurance, and the cover limits and call-out fee are set out below.
What do Intergas fault codes mean?
An Intergas fault code is a lockout code: the boiler has detected a problem, stopped, and put a number on the display so an engineer can see what it found. Most Intergas codes point at a temperature sensor, the fan, the flue, the gas valve or the flame signal, and nearly all of them are engineer work. A small handful, mainly low water pressure, air in the radiators, a frozen condensate pipe and a blocked flue terminal, you can safely check yourself first.
We could not find a fault code list anywhere on Intergas's consumer pages. Its troubleshooting page points you towards booking a repair rather than explaining what a code means. Every meaning below is taken from Intergas's own installation manuals: the Xtreme installation manual, the Xclusive installation manual, the Combi Compact HRE installation instructions, the Combi Compact ECO RF installation instructions, the Intergas Rapid installation manual and the Compact HRE OV installation instructions. They are free to download from the product literature section of the Intergas website.
There are two code schemes. The Xtreme 24, 30 and 36 and the Xclusive 24, 30 and 36 show three-digit codes with an F prefix. The Combi Compact HRE, Combi Compact ECO RF, Rapid and Compact HRE OV ranges show one- and two-digit numbers instead. People often drop the leading zeros when they search or type a code, so F1 usually means F001 and F31 usually means F031, but Intergas always prints the padded three-digit form.
One thing gets reported wrongly all over the web, so it is worth stating plainly: the two-digit numbers mean the same thing across all four of those ranges. The HRE, ECO RF, Rapid and Compact HRE OV manuals all group 10, 11, 12, 13 and 14 under a single fault, and all group 20, 21, 22, 23 and 24 under a single fault. A 12 is not a different fault from a 14. The only real differences are that the HRE, ECO RF and Rapid tables carry two codes the Compact HRE OV table does not: 0.0 and 5.
The gaps are deliberate. F013, F017, F020 to F026 and F030 are not labelled in either the Xtreme or the Xclusive installation manual, so they are left out here rather than guessed at.
Key facts
The short version before you scroll:
- Xtreme and Xclusive boilers show F-codes. Intergas labels 22 of them between F000 and F031, and a fault is signalled by a flashing service symbol with the code on the left display.
- HRE, ECO RF, Rapid and Compact HRE OV boilers show one- and two-digit numbers, and those numbers mean the same thing on all four ranges.
- Low water pressure, air in the radiators, a frozen outside condensate pipe and a blocked flue terminal are the only checks that are genuinely homeowner work. None of them mean opening the boiler casing.
- Anything involving gas, flame, the burner, the fan, a sensor or the PCB is a job for a Gas Safe registered engineer.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999 immediately.
- Smart Plan is a service plan, not insurance. On the boiler and central heating module, parts and labour are included up to £500 a year if your boiler is under 7 years old, or up to £200 a year if it is over 7. These are annual limits shared across every fault in the 12-month period, so a larger repair can cost more than the cover pays and you would cover the difference.
- Cover-plan call-outs run Monday to Friday, 08:00 to 18:00, with genuine emergencies, as defined in the plan terms, the only exception. A £95 call-out fee applies in the cases set out in the plan terms. Once you use a service, a 12-month agreement period begins.
Intergas Xtreme and Xclusive fault codes
These are the codes on the Intergas Xtreme 24, 30 and 36 and the Xclusive 24, 30 and 36. Both installation manuals print the same table, and all 22 labelled codes are below with the causes Intergas prints against each one. F010 and F011 share a single entry in the manual, so they share one row here.
Xtreme and Xclusive codes, F000 to F031
| Code | What it means | What to do |
|---|---|---|
| F000 | Sensor S0 is defective. S0 is the heat exchanger sensor. | Engineer only. The manuals list replacing heat exchanger sensor S0. |
| F001 | Temperature is too high during a central heating demand. | Part homeowner. The first listed cause is venting the heating system, so bleeding your radiators and checking the radiator valves are open is safe. A pump that does not operate, and the central heating flow sensor S1 or its wiring, are engineer work. |
| F002 | Temperature is too high during a hot water demand. | Engineer only. Wiring, position or operation of the hot water sensor S3, or a replacement S3. |
| F003 | Flue gas temperature is too high. | Engineer only. The manuals list checking the heat exchanger for contamination or debris, and checking the flue or chimney for blockages. |
| F004 | No flame during start-up. | Part homeowner for one check only. A blocked or frozen condensation drain is a listed cause, and thawing a frozen outside condensate pipe is safe. Everything else, the gas valve, gas inlet pressure, ignition and earthing, is gas work, so it needs a Gas Safe registered engineer. Smell gas? Call 0800 111 999 immediately. |
| F005 | Flame failure during normal operation. | Part homeowner for one check only. A blocked or frozen condensation drain is the first cause Intergas lists. Gas inlet pressure, ignition, gas valve adjustment, flue integrity and earthing are gas work, so they need a Gas Safe registered engineer. Smell gas? Call 0800 111 999 immediately. |
| F006 | Flame simulation. The boiler is reading a flame signal when it should not. | Engineer only, and it is gas work, so it needs a Gas Safe registered engineer. The manuals list replacing a faulty gas valve or a faulty PCB. Smell gas? Call 0800 111 999 immediately. |
| F007 | No or insufficient ionisation current. | Engineer only. The ionisation and ignition pin may be dirty, wrongly located or badly wired, or it may need replacing. |
| F008 | Incorrect fan speed detected. | Engineer only. Fan wiring, the fan assembly itself, or the PCB. |
| F009 | Internal PCB fault. | Engineer only. The manuals list replacing the PCB. |
| F010, F011 | Heat exchanger sensor S0 fault. Both manuals print F010 and F011 as one entry with the same checks. | Engineer only. Wiring to S0, S0 resistance values, correct location of S0, or a replacement S0. |
| F012 | Flue gas sensor fault S5. | Engineer only. Wiring to S5, S5 resistance values, correct location of S5, or a replacement S5. |
| F014 | Heat exchanger sensor S0 mounting fault. | Engineer only. S0 is not mounted correctly and has to be attached properly. It almost always follows recent work on the boiler. |
| F015 | Heating sensor S1 mounting fault. S1 is the central heating flow sensor. | Engineer only. The central heating flow sensor is not mounted correctly and has to be attached properly. |
| F016 | Hot water sensor S3 mounting fault. | Engineer only. The domestic hot water sensor S3 is not mounted correctly and has to be attached properly. |
| F018 | The flue and/or air supply duct is blocked or restricted. | Part homeowner. You can look at the flue terminal on the outside wall for an obvious obstruction such as debris, snow, a nest or plant growth. Checking or cleaning the ducts, and anything involving the seals or gaskets, is engineer work. |
| F019 | Boiler memory module fault. | Engineer only. The manuals list checking the BMM wiring or connector for damage, then replacing the BMM. |
| F027 | Short circuit of the outdoor weather compensation sensor S6. | Engineer only, and only relevant where an outdoor sensor is fitted. Wiring, resistance values, or a replacement outdoor sensor. |
| F028 | Reset error. | Worth checking yourself first. The manuals name unintentional operation of the reset button, for example while cleaning the control panel, as a cause. Stop touching the panel and let the boiler settle before you book anyone. Replacing the PCB is engineer work. |
| F029 | Gas valve fault. | Engineer only, and it is gas work, so it needs a Gas Safe registered engineer. The manuals list checking the gas valve wiring and coil resistances, then replacing the PCB. Smell gas? Call 0800 111 999 immediately. |
| F031 | Central heating flow sensor fault S1. | Engineer only. Wiring, S1 resistance values, correct operation of S1, or a replacement flow sensor. |
Intergas HRE, ECO RF, Rapid and Compact HRE OV codes
These are the one- and two-digit numbers on the Combi Compact HRE 24/18, 28/24, 36/30 and 36/40, the Combi Compact ECO RF 24, 30 and 36, the Rapid 25 and 32, and the Compact HRE OV 18, 24 and 30. All four installation manuals print the same table, so one list covers the lot.
Two points before you read it. First, several third-party sites split 10 to 14 and 20 to 24 into five separate faults each and invent a distinct meaning for every number. Intergas does not do that: it groups them. Second, 0.0 and 5 appear on the HRE, ECO RF and Rapid tables but not on the Compact HRE OV table.
HRE, ECO RF, Rapid and Compact HRE OV two-digit codes
| Code | What it means | What to do |
|---|---|---|
| 0 | Sensor fault after self check. | Engineer only. The manuals list replacing S1 and/or S2. Do not read a plain 0 as 0.0: they are different codes, and 0 is engineer work. |
| 0.0 | Low pressure, printed as a pressure sensor fault in the Rapid manual. On the HRE, ECO RF and Rapid tables only. | Part homeowner. Re-pressurise the central heating circuit through the filling loop. The HRE and Rapid manuals say to fill a cold system to between 1 and 2 bar. A blocked pressure sensor is the other listed cause, and that is engineer work. |
| 1 | Temperature too high. | Part homeowner. Air in the system, closed radiators and closed isolation valves are all listed causes, so bleeding your radiators and opening the valves is safe. A pump that is not running, poor circulation and a sticking flow switch are engineer work. |
| 2 | S1 and S2 interchanged. The two sensors are the wrong way round. | Engineer only. The manuals list checking the cable loom and replacing S1 or S2. It almost always follows recent work on the boiler. |
| 4 | No flame signal. The Rapid manual prints it as no flame signal after four ignition attempts. | Engineer only, and it is gas work, so it needs a Gas Safe registered engineer. A closed gas isolation valve or no gas at the meter is the first listed cause, so it is worth checking whether your other gas appliances still work. If the emergency control valve at your meter has closed, do not reopen it until an engineer knows why it tripped. Smell gas? Call 0800 111 999 immediately. |
| 5 | Poor flame signal, printed as no flame signal after four restart attempts in the Rapid manual. On the HRE, ECO RF and Rapid tables only. | Part homeowner for one check only. A blocked condensate drain is the first cause Intergas lists, and thawing a frozen outside condensate pipe is safe. Gas valve adjustment and earthing are gas work, so they need a Gas Safe registered engineer. Smell gas? Call 0800 111 999 immediately. |
| 6 | Flame detection fault. | Engineer only, and it is gas work, so it needs a Gas Safe registered engineer. The manuals list the ignition cable and spark plug cap, the ignition unit, then the boiler controller. Smell gas? Call 0800 111 999 immediately. |
| 8 | Incorrect fan speed. | Engineer only. The fan may be catching on the casing, or the wiring or contacts may be poor. |
| 10, 11, 12, 13, 14 | Sensor fault S1. All four manuals give these five numbers one shared meaning, so a 12 and a 14 are the same fault. | Engineer only. The manuals list venting the boiler at the manual air vent top left, which is inside the casing, then the hot water flow switch or flow sensor, the wiring, and replacing S1. This is not the same as bleeding your radiators. |
| 20, 21, 22, 23, 24 | Sensor fault S2, again one shared meaning across all five numbers. | Engineer only. The manuals list checking the wiring for a break and replacing S2. |
| 27 | Short circuit, outside sensor. | Engineer only, and only relevant where an outside sensor is fitted. The manuals list replacing the outside sensor. |
| 29, 30 | Gas valve relay faulty. | Engineer only, and it is gas work, so it needs a Gas Safe registered engineer. The manuals list replacing the ignition module and the boiler controller. Smell gas? Call 0800 111 999 immediately. |
Which Intergas faults can I safely deal with myself?
Four checks are genuinely homeowner work on an Intergas boiler, and none of them mean opening the casing.
1. Low water pressure. On an HRE, ECO RF or Rapid this shows as 0.0. On an Xtreme or Xclusive it is not a fault code at all: the pressure sits on the left display, and those manuals say that below 0.5 bar the display flashes during a central heating demand, and below 0.2 bar the demand is no longer met. Either way, top up through the filling loop while the system is cold. The Xtreme and Xclusive manuals say between 1 and 1.5 bar; the HRE and Rapid manuals say between 1 and 2 bar for a cold system. If the pressure drops again within days, you have a leak or a failed expansion vessel, and that needs an engineer.
2. Air in the system. F001 on an Xtreme or Xclusive, and code 1 on the two-digit ranges, both list air or poor circulation as a cause. Bleeding the radiators and making sure the radiator valves are actually open is safe, sensible and often enough. Be careful with one piece of wording: where Intergas prints venting the boiler against codes 10 to 14, it means the manual air vent inside the boiler casing, which is engineer work, not bleeding your radiators.
3. A frozen condensate pipe. F004 and F005 both list a blocked or frozen condensation drain, and so does code 5 on the HRE, ECO RF and Rapid ranges. In cold weather the white plastic pipe running outside from the boiler can freeze solid, and thawing it gently with warm, not boiling, water is a normal homeowner job.
4. A blocked flue terminal. F018 is a flue or air supply duct blockage or restriction. Looking at the terminal on the outside wall for leaves, snow, a nest or plant growth costs nothing. Clearing anything inside the flue, or touching the seals and gaskets, is engineer work.
Resetting is the other common question. On an Xtreme or Xclusive you reset by touching the flashing service symbol and holding it for two seconds. Both manuals warn that a reset is not possible when a component is outside its tolerance values, and say that if the fault code reoccurs an Intergas trained engineer should be requested. On the HRE, ECO RF, Rapid and Compact HRE OV ranges you press the reset key on the operating panel once the fault has been rectified. Either way, reset once, and if the same number returns, stop.
Everything else on the two tables above is engineer work. The sensors, the fan, the PCB, the boiler memory module, the ionisation pin, the gas valve and the flue all sit inside the casing, and several of them are gas components.
When to call a Gas Safe registered engineer
Call an engineer for any code touching gas, the burner or combustion. On an Xtreme or Xclusive that means F004, F005, F006 and F029. On the two-digit ranges it means 4, 5, 6, 29 and 30. Also call if a code returns after one reset, or if the boiler locks out repeatedly over a day or two. Anyone working on the gas side of your boiler must be Gas Safe registered, and you can check that yourself on the Gas Safe Register.
If you smell gas or suspect a gas leak, do not wait for an appointment. Call the National Gas Emergency Service on 0800 111 999 immediately, and make that call from a location away from the leak. The Intergas manuals set out the same procedure: do not smoke, use a lighter or strike matches; do not operate electrical switches, unplug equipment, use the telephone or ring doorbells; turn off the gas at the meter or regulator; open windows and doors; warn your neighbours and leave the building. If your boiler runs on LPG, call the supplier's number on the side of the gas tank or cylinder.
You can book a one-off repair with us and we will arrange for a Gas Safe registered engineer to attend. We aim to get an engineer out to you within two working days, and one-off repair visits run Monday to Friday, 09:00 to 17:00. A £95 call-out fee applies to a one-off repair, paid in advance, and one-off repairs do not carry a workmanship guarantee. Or call us on 0333 772 6247 if you would rather talk it through first.
If you would rather spread the cost, the Smart Plan boiler and central heating module covers parts and labour up to £500 a year if your boiler is under 7 years old, or up to £200 a year if it is over 7. That is an annual limit shared across every fault in the 12-month period, so a bigger repair can cost more than the cover pays and you would cover the difference. Cover is modular, so you pick only the modules you want, and the limits apply only to the modules on your cover sheet. A £95 call-out fee applies in the cases set out in the plan terms, including your first 30 days, during which cover still applies. Cover-plan call-outs run Monday to Friday, 08:00 to 18:00, with genuine emergencies, as defined in the plan terms, the only exception. Once you use a service, a 12-month agreement period begins, and leaving early costs the remaining months or 75% of the outstanding balance. A 14-day cooling-off period applies and voids once a service is used. Smart Plan is a service plan, not insurance, provided by UK Boiler Company Ltd, trading since 2014.
One thing to be clear about before you sign up: cover is for future breakdowns, not for a fault your boiler is already showing. An Intergas code on the display today counts as pre-existing and would not be covered, so book a one-off repair for that one.
Intergas fault code FAQs
Where does Intergas publish its fault codes?
Inside its installation manuals, not on its website. The Intergas troubleshooting page points you towards booking a repair rather than explaining what a code means. The code tables live in the Xtreme installation manual, the Xclusive installation manual, the Combi Compact HRE installation instructions, the Combi Compact ECO RF installation instructions, the Intergas Rapid installation manual and the Compact HRE OV installation instructions, all free to download from the documentation tab on each Intergas product page.
Why does my Intergas boiler show a two-digit code instead of an F code?
Because of its control board. The Xtreme and Xclusive ranges show three-digit codes with an F prefix, and Intergas labels 22 of them between F000 and F031. The Combi Compact HRE, Combi Compact ECO RF, Rapid and Compact HRE OV ranges show one- and two-digit numbers instead. Both are normal fault codes, they just come from different generations of controller.
Does code 12 mean the same on every Intergas boiler?
Yes, on the ranges that use two-digit codes. The HRE, ECO RF, Rapid and Compact HRE OV manuals all print 10, 11, 12, 13 and 14 as one grouped entry meaning sensor fault S1, and 20 to 24 as one grouped entry meaning sensor fault S2. Some third-party sites split them into five separate faults each and invent a distinct meaning per number. Intergas does not, so treat any page that gives 12 its own unique meaning with caution.
What does 0.0 mean on an Intergas boiler?
Low pressure. It appears in the fault code table of the HRE, ECO RF and Rapid manuals, and the Rapid manual prints it as a pressure sensor fault. The listed remedies are to re-pressurise the central heating circuit through the filling loop, or, if that does not hold, a blocked pressure sensor, which is engineer work. Read it carefully on a small display: a plain 0 is a different code, sensor fault after self check, and that one is engineer work.
Can I reset my Intergas boiler after a fault code?
Once. On an Xtreme or Xclusive you touch the flashing service symbol and hold it for two seconds. Both manuals say a reset is not possible when a component is outside its tolerance values, and that if the fault code reoccurs an Intergas trained engineer should be requested. On the HRE, ECO RF, Rapid and Compact HRE OV ranges you press the reset key on the operating panel once the fault has been rectified. Repeated resetting is not a fix.
Is an Intergas fault code dangerous?
A lockout is the boiler protecting itself, so most codes are safe in the sense that the boiler has stopped rather than carried on. Gas-related codes still need a Gas Safe registered engineer promptly. If you ever smell gas or suspect carbon monoxide, call the National Gas Emergency Service on 0800 111 999 straight away rather than waiting for an appointment.
Does Smart Plan cover the full cost of an Intergas repair?
Not always. On the boiler and central heating module, parts and labour are covered up to £500 a year if your boiler is under 7 years old, or up to £200 a year if it is over 7. That is an annual limit shared across every fault in the 12-month period, so a larger repair can cost more than the cover pays and you would cover the difference. Cover is modular, so the limits apply only to the modules on your cover sheet. A £95 call-out fee applies in the cases set out in the plan terms, and once you use a service a 12-month agreement period begins. Cover is for future breakdowns, so a code already showing on your display counts as pre-existing and would not be covered.
Intergas code still showing after the safe checks?
Book a one-off repair, or set up a Smart Plan boiler and central heating module for future breakdowns. A one-off repair carries a £95 call-out fee, paid in advance, visits run Monday to Friday, 09:00 to 17:00, and one-off repairs do not carry a workmanship guarantee. The module is a service plan, not insurance: parts and labour up to £500 a year if your boiler is under 7 years old, or up to £200 a year if it is over 7, as an annual limit shared across all faults, so a bigger repair can cost more than the cover pays. A £95 call-out fee applies in the cases set out in the plan terms; cover-plan call-outs run Monday to Friday, 08:00 to 18:00, with genuine emergencies, as defined in the plan terms, the only exception; and once you use a service a 12-month agreement period begins. A code already on your display counts as pre-existing and would not be covered.