No hot water from your boiler? Start with which boiler you have
On a combi, no hot water while the heating still works most likely points to the diverter valve inside the boiler. On a boiler with a hot water cylinder, the things to check are the programmer, the cylinder thermostat, the immersion switch and the valves on the pipework. If there is no heating either, the boiler itself has stopped: check the display, the pressure gauge and, in freezing weather, the condensate pipe. The tables below match each symptom to the likely cause, what you can safely check, and when to call an engineer.
Smell gas? Stop here
If you can smell gas, do not run any of the checks on this page. Call the National Gas Emergency Service on 0800 111 999. The Health and Safety Executive also advises opening all the doors and windows and shutting off the gas at the meter control valve if you know where it is.
Do not open the boiler casing. Everything on this page is done from the outside of the boiler, at the controls, or at the cylinder dial and switches. Anything inside the boiler is a job for a Gas Safe registered engineer.
Which type of boiler do you have?
Ideal Heating puts it simply. A combi heats water on demand when you turn on a tap, and its hot water is fed by mains pressure, so there is no tank or cylinder. A system boiler is also fed by mains pressure, but the hot water comes from a cylinder. A heat-only (regular) boiler is fed by gravity from a tank and a cylinder.
If you have a cylinder in an airing cupboard or utility room, use the second table. If you have no cylinder, use the first. Our guides to combi boilers and system boilers explain the difference in more detail.
Before you start, open a cold tap. If no water comes out of any tap, hot or cold, the problem is the water supply, not the boiler.
Combi boiler: symptom, likely cause and what to do
| What you notice | Likely cause | What you can safely check | When it needs an engineer |
|---|---|---|---|
| No hot water, but the heating works | The diverter valve stuck in the heating position. It is the part inside the boiler that switches the heat between the radiators and the taps. | Check the hot water temperature is turned up on the front of the boiler, and the isolation valve on the cold mains pipe under the boiler is open. Ideal also suggests turning the hot taps on and off a few times while the heating is on. | If those checks fail. A diverter valve sits inside the boiler, so only a Gas Safe registered engineer can free or replace it. |
| Hot water only comes through when the heating is on | A faulty diverter valve. Vaillant lists this as one of the signs. | Check the boiler's hot water setting is switched on and turned up. | Straight away once the setting is right. Vaillant says to call a Gas Safe registered engineer rather than try to fix the valve. |
| Hot water runs hot, then goes cold after a minute | The boiler switching off. Ideal says a boiler switches off if its sensors detect a fault, and Vaillant says it turns off if the pressure drops too low. The manufacturer pages we checked do not name this exact pattern. | Watch the display for a fault code as the water goes cold, and check the pressure gauge. | If a fault code shows each time, or the pressure keeps dropping. |
| No hot water and no heating | No power or gas to the boiler, low pressure, a frozen condensate pipe in freezing weather, or a fault that has locked the boiler out. | Check the display, the power, that other gas appliances work, the pressure gauge and, in freezing weather, the condensate pipe outside. Reset once if your manual says so. | If the boiler will not restart after those checks, or the same fault code comes back. |
| Lukewarm water only, radiators heat up fine | The hot water temperature set low, or a diverter valve that is stuck and letting some hot water pass, which Vaillant lists as a sign. | Check the hot water temperature on the boiler. Ideal says water set below 30°C will feel quite cold. | If the setting is right and the water is still lukewarm. That points to the diverter valve. |
| Hot water at some taps but not others | Several outlets sharing the boiler's output. A combi's temperature rise depends on the flow passing through it. | Try each hot tap on its own. If every tap runs hot on its own, the cause is the shared flow rather than a fault. | If one tap stays cold even when it is the only one running. |
System or regular boiler with a hot water cylinder: symptom, likely cause and what to do
| What you notice | Likely cause | What you can safely check | When it needs an engineer |
|---|---|---|---|
| No hot water, but the heating works | The programmer set to heating only, the cylinder thermostat set too low, a zone or motorised valve not opening, or an immersion heater switched off. | Check the hot water channel on the programmer is on and the clock is right. Check the cylinder thermostat dial, if you can see it without removing a cover. Check the immersion switch is on. | A zone or motorised valve, or anything behind the cylinder's covers. Leave those to a competent installer. |
| Hot water only when the heating is on | None of the manufacturer pages we checked names this exact symptom, so we do not give a likely cause for it. | Check the programmer's hot water times separately from the heating times. | If the hot water channel is on and the cylinder still only heats with the heating. A competent installer needs to trace the cause. |
| Hot water runs out after a short while | The cylinder has used up its stored hot water, or it was never heated because the timer was not set to heat it. | Check the programmer was due to heat the cylinder. After heavy use, give it time to heat up again. | If the cylinder never gets hot even with the hot water channel on. |
| No hot water and no heating | No power or gas to the boiler, low pressure on a sealed system, a frozen condensate pipe in freezing weather, or a fault lockout. | Check the display, the power, that other gas appliances work and the pressure gauge. Thaw the condensate pipe only as your manufacturer describes. Reset once if your manual says so. | If the boiler will not restart after those checks, or the same fault code comes back. |
| Lukewarm water only | The cylinder thermostat set too low. | Check the cylinder thermostat setting. Viessmann says hot water in a cylinder should be set to a minimum of 60 degrees. | If the setting is right and the cylinder never gets properly hot. |
| Hot water at some taps but not others | An airlock: air trapped in the pipes, blocking hot water from reaching some taps. | Note which taps are affected and whether the cold supply to them runs normally. | Vaillant says to have a Gas Safe registered engineer look at an airlock, which may mean draining the system. |
The safe checks, one by one
None of these involves the gas supply or the inside of the boiler. Stop at any point you are not sure about.
Read the boiler display and any fault code
Ideal Heating says that if the sensors in the boiler detect a fault, they switch the boiler off, and to check your handbook for what the message means. Viessmann says some fault codes can be cleared with a simple reset, while others need professional attention. Write the code down exactly as it shows. Our boiler fault codes by brand hub explains the common ones.
Check the power and the gas
The Worcester Bosch user instructions list the basic checks to make before you report a fault: is the electrical power switched on to the boiler, is the cold water main turned on, are other gas appliances such as the hob working, and has the credit run out on a gas prepayment meter? Ideal Heating adds that if only the boiler is off, check whether its switch on the consumer unit (fuse box) has tripped.
Check the pressure gauge
Worcester Bosch's basic checks ask whether the pressure is between 1 and 1.5 bar when the boiler is cold. Vaillant says low boiler pressure can result in cold radiators and no hot water, because the system turns off automatically if the pressure is too high or too low. Figures vary by model, so check your own manual. Our pages on what boiler pressure should be, how to increase boiler pressure and a boiler that keeps losing pressure take it from there.
Check the programmer and the hot water setting
Vaillant says a timer can change through an accidental edit or a power cut. Viessmann says to check the timer shows the right time and date, has not run out of batteries, and is programmed for both heating and hot water. Viessmann's combi advice adds that the hot water may simply have been switched off by mistake. On a combi, Ideal's FAQ says to check the hot water temperature is turned up on the front of the boiler.
If the room thermostat or the controls seem to be at fault, our guides to room thermostat problems and a thermostat not controlling the boiler go further.
On a cylinder: the thermostat and the immersion switch
The fault finding chart in Heatrae Sadia's Megaflo Eco SystemFit product guide lists the causes of cold water from the hot tap on that cylinder. They include an immersion heater not switched on, a programmer set to central heating only, a thermal cut-out that has operated, a boiler that is not working, and a motorised valve not connected correctly.
Checking the immersion switch is on, and setting the programmer to a hot water programme, are homeowner jobs. Worcester Bosch's basic checks also ask whether the cylinder thermostat is set too low, so check its dial if you can see it without taking a cover off.
Resetting a thermal cut-out is not. On that cylinder the immersion thermostat and cut-out sit under the immersion heater cover, and the same guide says any work on the cylinder and its controls must be carried out by a competent installer, with the electricity disconnected before any cover comes off. It also says a cut-out must never be bypassed.
Reset once, only if your manual says so
Vaillant says to fix the cause first, then restart the boiler. The Worcester Bosch instructions say that if a fault persists after a reset, contact your installer or the manufacturer's customer service and give them the fault code. Our guide on how to reset a boiler has the steps by brand. If the same fault comes back, do not keep resetting it.
In freezing weather: the condensate pipe
The Worcester Bosch user instructions say a frozen or blocked condensate pipe will cause the boiler to shut down. Vaillant says its boilers show an F28 or F29 code, and you may hear gurgling or bubbling. The manufacturers' own steps, in short:
- Only thaw a pipe that is at ground level and easy to reach. Worcester Bosch says never to attempt it on a pipe at height.
- Find the blockage. It is most likely at the most exposed point outside, such as the open end, a bend or a sag in the pipe.
- Warm the pipe with a hot water bottle, a microwaveable heat pack or a cloth soaked in hot water, or pour warm water over it from a watering can. Never use boiling water: Vaillant says it can damage or crack the pipe.
- Take care on the ground. Baxi warns about slipping, and Worcester Bosch says the water can freeze again and create a slip hazard.
- Reset the boiler as your manual describes. If it will not restart, or the pipe keeps freezing, call an engineer.
Baxi's thawing guide gives the same steps. Our page on a blocked condensate pipe covers what to do next.
What needs an engineer
Stop and book someone once the safe checks are done and any of these apply.
- The diverter valve on a combi. Viessmann says a diverter valve stuck in the heating position, or one that has developed a fault, can leave you with no hot water, and that you will need a Gas Safe registered engineer to fix or replace it. Vaillant says any work on a gas appliance is dangerous. Our page on a faulty diverter valve explains the part.
- A zone or motorised valve on a cylinder system. For a heat-only or system boiler where the heating works but the hot water does not, Ideal's FAQ says this is likely a system problem, possibly a zone valve not operating.
- A thermal cut-out, a cylinder thermostat behind a cover, or immersion wiring. Those are for a competent installer.
- An airlock. Vaillant says to consult a Gas Safe registered engineer, and the system may need draining.
- A fault code that comes back after one reset, pressure that keeps dropping, or a condensate pipe that keeps freezing.
- No hot water and no heating with no obvious cause. Vaillant says it is always best to call a Gas Safe registered engineer to inspect the boiler.
If you have hot water but cold radiators instead, our guide to hot water but no heating covers that the other way round.
Where the safe line is
Reading the display, checking the power and the pressure gauge, setting the programmer, the hot water temperature and the cylinder thermostat dial, switching the immersion on, one reset as your manual describes, and thawing a ground-level condensate pipe as the manufacturer describes are homeowner jobs. Opening the boiler casing, the cylinder's electrical covers, or anything to do with the gas supply is not.
The Health and Safety Executive says anyone employed to work on gas appliances in a home must be a Gas Safe registered engineer and competent in that area of gas work. Their competencies are marked on the back of their Gas Safe Register ID card, so check it before work starts.
If you smell gas at any point, stop. Call the National Gas Emergency Service on 0800 111 999.
Does Smart Plan cover no hot water?
It depends on the cause, and several causes on this page sit outside the plan. Smart Plan is a service plan, not insurance. The boiler and central heating cover module pays parts and labour on the equipment listed on your cover sheet, up to £500 in each 12-month period while the boiler is under 7 years old, or £200 once it is over 7.
The terms exclude adjusting settings, replacing batteries, resetting equipment and repressurising, and any works where the cause is freezing. The boiler and central heating module also excludes works on unvented cylinders, thermal stores and immersion heaters, although a hot water cylinder is covered for a call-out related to a leak where your cover sheet includes it. A fault we identify as already existing before your agreement started counts as a defect under the terms, and repairing it is excluded.
A £95 call-out fee applies in the situations set out in the terms, including the first 30 days of a new agreement and faults the plan does not cover. Cover-plan call-outs take place Monday to Friday, 08:00 to 18:00, unless it is an emergency breakdown.
If you are not on a plan, we also arrange one-off repairs: our no hot water repair page sets out how a visit works, and our boiler repair page covers other faults. The full cover plan terms and conditions set out exactly what is included.
Still no hot water after the checks?
Tell us what type of boiler you have, what the hot water is doing and any code on the display, and we will call you back to talk it through. Our aim is to ring you back within one working day, Monday to Friday, 08:00 to 18:00.
Sources, checked November 2026
We put this guide together from the manufacturer and safety pages below, which we opened and checked in November 2026. Your own boiler's manual comes first wherever it differs.
- Worcester Bosch: Greenstar 8000+ user instructions, 6721890748 (2024/06)
- Ideal Heating: no hot water? Here's what to do
- Ideal Heating: why can't I get hot water? (boiler faults FAQs)
- Baxi: what to check if you have no hot water
- Baxi: how to thaw a frozen boiler condensate pipe
- Vaillant: no hot water? What to check
- Vaillant: how to fix a boiler diverter valve
- Vaillant: most common boiler problems
- Vaillant: how to thaw a frozen boiler condensate pipe
- Viessmann: no hot water? Here's what to check
- Viessmann: my boiler is working but I have no hot water
- Heatrae Sadia: Megaflo Eco SystemFit product guide, fault finding chart
- Health and Safety Executive: domestic gas safety FAQs