Radiators not heating up? Start with where they are cold

Where a radiator is cold tells you most of what is wrong. Cold at the top usually means trapped air, which you can bleed. Cold at the bottom usually means sludge, which needs a heating engineer. One cold radiator often has a closed or stuck valve. Every radiator cold usually points to the boiler, its settings or the controls. The table below matches each pattern to the likely cause, what you can safely check yourself, and when to stop and call someone.

Smell gas? Stop here

If you can smell gas, do not run any of the checks on this page. Call the National Gas Emergency Service on 0800 111 999. The Health and Safety Executive also advises opening all the doors and windows and shutting off the gas at the meter control valve if you know where it is. Do not use a gas appliance you think is unsafe until a Gas Safe registered engineer has checked it.

First, feel every radiator

Before you change anything, find out exactly where the cold is. Turn the heating on, turn the room thermostat up, and turn every radiator on, which is how Viessmann sets the system up before bleeding. Give the boiler time to warm the house through.

Then walk round with your hand out. On each radiator, feel the top and the bottom, and both ends. Note which rooms are cold, and whether the cold ones are upstairs, downstairs or all over the house. Feel the pipes going into a cold radiator as well. Take care, because pipes and radiators can be hot enough to hurt.

Last, look at the boiler. Note what the pressure gauge reads, whether a fault code is showing, and whether you still have hot water at the taps. With those answers, the table below will point you to the right branch.

Symptom, likely cause and what to do

What you noticeLikely causeWhat you can safely doWhen it needs an engineer
Cold at the top, warm at the bottomTrapped air. Air rises to the top of the radiator and stops hot water filling it.Bleed the radiator, then check the boiler pressure gauge, because bleeding lets water out.If radiators need bleeding again and again. Baxi lists that as one of the signs of sludge.
Warm at the top, cold along the bottomSludge settled in the bottom of the radiator, blocking the flow.Check both valves are open. Do not bleed it: bleeding only removes air, and the cold half will stay cold.Clearing sludge means flushing the radiator or the whole system. Vaillant says flushing must be done by a heating engineer.
One radiator cold all over, the rest are fineA closed valve, a thermostatic valve (TRV) with its pin stuck down, or air in that radiator.Check the TRV is turned up and the small valve at the other end (the lockshield) is open. Take the TRV head off and check the pin springs back.If the pin will not free without force, the valve leaks, or the valve needs replacing.
Cold downstairs, hot upstairsThe system is out of balance. Hot water rises, so the upper radiators take more than their share.Partly close the lockshield valves on the upstairs radiators so more hot water reaches downstairs.If the quick fix does not work, the whole system needs balancing, radiator by radiator.
Cold upstairs, warm downstairsAir, which gathers at the high points of a system, or low boiler pressure.Bleed the upstairs radiators, then check the gauge. Top up the pressure if it is low, following your boiler's manual.If the pressure keeps dropping and you are topping up much more often than once or twice a year.
All radiators cold, but hot water is fineThe boiler is set to hot water only, the thermostat or timer is not asking for heat, or on a combi boiler, a stuck diverter valve.Check the boiler is not in summer or hot-water-only mode. Turn the thermostat above the room temperature and check the timer is on.A diverter valve sits inside a combi boiler: call a Gas Safe registered engineer. On a system or heat-only boiler the controls are the usual cause, and Ideal says to call a plumber, not the boiler maker.
All radiators cold and no hot water eitherThe boiler itself is not running: a fault, a lockout, low pressure or no power or gas.Check for a fault code, check the pressure gauge, and check the boiler has power. Reset it once only if your manual says you can.Anything beyond those checks. Most boiler faults must be fixed by a Gas Safe registered engineer.
Every radiator lukewarm, none properly hotThe boiler's heating temperature set low, sludge through the whole system, or a pump that is not circulating the water.Check the heating temperature setting on the boiler against its manual. Listen for the pump and look for a power light on it.Pump faults and system-wide sludge are heating engineer jobs. Never open the boiler casing to reach a pump.

The safe checks, one by one

Each of these is a homeowner job. None of them involves the gas supply or the inside of the boiler.

Bleed a radiator that is cold at the top

Worcester Bosch says a radiator that needs bleeding will be colder at the top than at the bottom. Its steps, in short:

  1. Turn the heating off and wait for the radiators to cool.
  2. Hold a cloth under the bleed valve at the top of the radiator, put the radiator key in, and turn it anti-clockwise. You will hear a hiss as the air escapes.
  3. When water starts to flow steadily, turn the key clockwise to close the valve, and wipe up the drips.
  4. When you have bled every radiator that needed it, check the boiler pressure and top it up if it has dropped.

Our full guide to bleeding a radiator goes through each step. If the radiator is cold at the bottom instead, bleeding will not help: our page on a radiator cold at the bottom explains why.

Check the boiler pressure gauge

Worcester Bosch says that when the heating is cool, the gauge should read between 1 and 1.5 bar. Below 0.5 bar means water has been lost from the system and must be replaced. Vaillant says low boiler pressure can result in cold radiators and no hot water. Figures vary by model, so check your own boiler's manual.

Worcester Bosch also says a system will usually need topping up once or twice a year, and to contact your installer if you are repressurising much more often. Our pages on what boiler pressure should be, how to increase boiler pressure and a boiler that keeps losing pressure pick up from here.

Check the thermostat, the timer and the boiler mode

Vaillant says to check first that the thermostat is set above the current room temperature. It also says a combi boiler is often left on hot water only after the summer. Its cold radiator advice adds that a boiler may be set to come on at an unexpected time, or to heat radiators only to a certain temperature. Wilo, which makes heating pumps, also suggests checking whether a timer or night setback is active.

If the thermostat seems to be the problem, our guides to room thermostat problems and a thermostat not controlling the boiler go further. If the thermostat has failed completely, see how to turn the heating on without a thermostat.

Open the valves, and free a stuck TRV pin

Most radiators have a valve at each end. One is the thermostatic radiator valve (TRV) with the numbered head. The other is the lockshield, which Viessmann describes as the smaller valve at the opposite end to the thermostat. Baxi says radiator valves tend to get stuck, particularly if the radiator has not been used for a while.

  1. Turn the TRV head up to its highest number.
  2. If the radiator stays cold, take the head off. Viessmann says you will find a pin underneath, and when you press it, it should spring back up.
  3. If the pin stays down or moves stiffly, the valve is probably the cause. Viessmann suggests freeing it gently with pliers and a little grease, without excessive force, and calling a professional if that does not work.
  4. Check the lockshield is open. If someone has turned it right down, open it a little and note how many turns you made, so you can put it back.

Rebalance when downstairs is cold

Viessmann says cold radiators downstairs can show a balancing issue, because hot water tends to rise. Its quick fix is to close the lockshield on the upstairs radiators and then open it a quarter turn, which encourages more heat to flow downstairs. If that is not enough, it says the whole system may need balancing. Vaillant also suggests checking whether radiators need balancing before you switch the heating back on for winter.

Listen for the pump

Wilo suggests three questions when the heating fails: is there any warmth in the radiators at all, can you hear the pump working, and does the pump have a power light showing that it has power. Some warmth means the boiler is working. That is as far as a homeowner should go with a pump.

What needs a heating engineer

Stop and book someone once the safe checks are done and any of these apply.

  • Sludge. Radiators cold at the bottom, or still cold after bleeding, may mean the system needs flushing. Vaillant says this must be done by a heating engineer. Baxi's list of sludge signs includes pipes to a radiator getting hot while the radiator does not, and the pipe out of the boiler being hot while the pipe coming back is lukewarm or cold. Our page on central heating sludge and power flushing explains what the work involves.
  • The pump. A pump that is silent, or has no power light, while the boiler is firing needs testing by an engineer. Baxi lists a pump that leaks or fails among the signs of sludge, so ask whether the system water should be checked too.
  • The diverter valve on a combi boiler. Vaillant says hot showers with cold radiators can point to a faulty diverter valve, and recommends calling a qualified heating engineer instead of trying to fix it yourself, because any work on a gas appliance is dangerous. Our page on a faulty diverter valve and our page on hot water but no heating cover this branch.
  • Hot water but no heating on a system or heat-only boiler. Ideal says these boilers respond to one demand, to heat water, and the controls do the rest. For this fault it says to contact a plumber, not the boiler maker.
  • Balancing the whole system, when the quick lockshield fix has not worked.
  • A radiator valve that will not free, leaks, or needs replacing.
  • Pressure that keeps dropping, or a fault code your manual says needs an engineer. Our hub of boiler fault codes by brand is linked below.

Where the safe line is

Bleeding radiators, reading the pressure gauge, topping up as your manual shows, setting the thermostat and timer, and turning radiator valves are homeowner jobs. Opening the boiler casing, or doing anything to the gas supply or the parts inside the boiler, is not.

The Health and Safety Executive says anyone employed to work on gas appliances in a home must be a Gas Safe registered engineer and competent. Gas Safe registered engineers carry an ID card showing which appliances they are qualified to work on, so check it before work starts.

If you smell gas at any point, stop. Call the National Gas Emergency Service on 0800 111 999.

Does Smart Plan cover cold radiators?

It depends on the cause. Smart Plan is a service plan, not insurance. The boiler and central heating cover module pays parts and labour on the equipment listed on your cover sheet, up to £500 in each 12-month period while the boiler is under 7 years old, or £200 once it is over 7.

Some causes of cold radiators sit outside it. The terms exclude replacement or repair of radiators themselves, and the general exclusions rule out work relating to or caused by sludge, scale deposits or contamination from rust and corrosion. So a flush, or a new radiator, is your cost either way.

A £95 call-out fee applies in the situations set out in the terms, including the first 30 days of a new agreement and faults the plan does not cover. Cover-plan call-outs take place Monday to Friday, 08:00 to 18:00, unless it is an emergency breakdown.

If you are not on a plan, we also arrange one-off boiler repairs, and our no heating page sets out how a one-off visit works. The full cover plan terms and conditions set out exactly what is included.

Still cold after the checks?

Tell us which radiators are cold and what the boiler is showing, and we will call you back to talk it through. Our aim is to ring you back within one working day, Monday to Friday, 08:00 to 18:00.

Get a call back to set up cover

A service plan, not insurance. Nothing is paid online.